vectron international www.vectron.com v. 2006 - 11 - 10 page 1 of 5 vectron international headquarters 267 lowell road hudson, new hampshire 03051 + 1 - 888 - 328 - 7661 tel + 1 - 888 - 329 - 8328 fax vectron international llc. 1 00 watts street mount holly springs, pa 17065 usa +1 - 717 - 486 - 3411 tel +1 - 717 - 486 - 5920 fax vectron international gmbh & co. kg landstrasse d - 74924 neckarbischofsheim germany +49 - 07268 - 801 - 0 tel +49 - 07268 - 801 - 281 fax vectron asia pacific sales office 1f - 2f, no 8 workshop, no 308 fenju road, waigaoqiao free trade zone, pudong, shanghai, p.r. china 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax c4500 ocxo typical applications features base stations surface mount package optional test equipment reflow process compatible optional synthesizers at - cut and sc - cut crystal options digital switching low profile compact package previous vectron model numbers oco50, oco1000, mc4004x4 frequency range 6 mhz ? 6 0 mhz standard frequencies 8.192; 10; 12, 12.8; 16.384;20; 32.768 ; 38.88 mhz frequency stabilities 1 [at cut crystal ? standard] parameter min typ max. units operating temp range ordering code vs. o perating temperature range - 50 +50 ppb - 2 0 ? +70c d 508 (referenced to +25 c) - 1 00 + 1 00 ppb - 20 ? +70c d 1 07 - 1 00 + 1 00 ppb - 40 ? +85c f 1 07 parameter min typ max. units condition initial tolerance vs. supply voltage change vs. load change vs. aging / day vs. aging / year - 5 00 - 10 - 10 - 5 .0 - 250 + 5 00 +10 +10 + 5 .0 +250 ppb ppb ppb ppb ppb at time of shipment, nominal efc v s 5% load 5% after 3 0 days of operation after 3 0 day s of operation warm - up time 3 minutes to 100ppb of fi nal frequency (1 hour reading) @ +25c frequency stabilities 1 [sc cut crystal ? option] parameter min typ max. units operating temp range ordering code vs. operating temperature range - 10 +10 ppb - 2 0 ? +70c d 108 (referenced to +25 c) - 20 +20 ppb - 20 ? +70c d208 - 20 +20 ppb - 40 ? + 85 c f 258 parameter min typ max. units condition initial tolerance vs. supply voltage change vs. load change vs. aging / day vs aging / y ear - 2 00 - 2.0 - 5.0 - 1.0 - 75 + 2 00 +2.0 +5.0 +1.0 + 75 ppb ppb ppb ppb ppb at time of shipment, nominal efc v s 5% load 5% after 3 0 day s of operation after 3 0 days of operation warm - up time 3 minutes to 10ppb of final frequency (1 hour reading) @ +25c supply voltage (vs) parameter min typ max. units condi tion ordering code supply voltage [standard] 4.75 5 5.25 vdc sv050 supply voltage [option] 11.4 12.0 12.6 vdc sv120 supply voltage [option] 3.135 3.3 3.465 vdc sv033 power consumption 3.0 watts during warm - up 1.0 watts steady state @ +25c
vectron international www.vectron.com v. 2006 - 11 - 10 page 2 of 5 vectron international headquarters 267 lowell road hudson, new hampshire 03051 + 1 - 888 - 328 - 7661 tel + 1 - 888 - 329 - 8328 fax vectron international llc. 1 00 watts street mount holly springs, pa 17065 usa +1 - 717 - 486 - 3411 tel +1 - 717 - 486 - 5920 fax vectron international gmbh & co. kg landstrasse d - 74924 neckarbischofsheim germany +49 - 07268 - 801 - 0 tel +49 - 07268 - 801 - 281 fax vectron asia pacific sales office 1f - 2f, no 8 workshop, no 308 fenju road, waigaoqiao free trade zone, pudong, shanghai, p.r. china 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax c4500 ocxo rf output parameter min typ max. units condition ordering code signal [standard] hcmos rfh load 15 pf signal level (vol) 0.5 vdc with vs=12.0v or 5.0v and 15pf load 0.3 vdc with vs=3.3v and 15pf load signal level (voh) 4.5 vdc with vs= 12.0v or 5.0v and 15pf load 3.0 vdc with vs=3.3v and 15pf load duty cycle 45 55 % @ (voh - vol)/2 signal [option] sinewave rfs load 50 output power @3,3v supply volt. 2 5 8 dbm 50 ohm load harmonics power@5v 5 8 - 30 11 dbc dbm 50 ohm load 50 ohm load frequency tuning (efc) parameter min typ max. units condition ordering code 5 tuning range fixed ocxo; no adjust 0 tuning range 1.0 1 .75 2 .5 ppm with sc cut crystal 1 3 .0 5 .0 8 ppm with at cut crystal 1 linearity 5 % tuning slope positive control voltage range 0.0 2.0 4.0 vdc with vs=5.0vdc 0.0 2.0 4.0 vdc with vs=12vdc 0.0 1.4 2.8 vdc with vs=3.3vdc referenc e voltage output (vref) parameter min typ max. units condition reference voltage 3.92 4.0 4.08 vdc with vs=5.0vdc 4.9 5.0 5.1 vdc with vs=12vdc 2.75 2.8 2.85 vdc with vs=3.3vdc additional parameters parameter min typ max. units condition phase n oise 3 - 90 dbc/hz 1 hz with 10 mhz sc cut - 120 dbc/hz 10 hz - 140 dbc/hz 100 hz - 145 dbc/hz 1 khz - 150 dbc/hz 10 khz phase noise 3 - 75 dbc/hz 1 hz with 10 mhz at cut - 105 dbc/hz 10 hz - 130 dbc/hz 100 hz - 140 dbc/hz 1 k hz - 150 dbc/hz 10 khz weight 14 g processing & packing handling & processing note absolute maximum ratings
vectron international www.vectron.com v. 2006 - 11 - 10 page 3 of 5 vectron international headquarters 267 lowell road hudson, new hampshire 03051 + 1 - 888 - 328 - 7661 tel + 1 - 888 - 329 - 8328 fax vectron international llc. 1 00 watts street mount holly springs, pa 17065 usa +1 - 717 - 486 - 3411 tel +1 - 717 - 486 - 5920 fax vectron international gmbh & co. kg landstrasse d - 74924 neckarbischofsheim germany +49 - 07268 - 801 - 0 tel +49 - 07268 - 801 - 281 fax vectron asia pacific sales office 1f - 2f, no 8 workshop, no 308 fenju road, waigaoqiao free trade zone, pudong, shanghai, p.r. china 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax c4500 ocxo parameter min typ max. units condition supply voltage (vs) 7.0 v with vs=5.0vdc 15.0 v with vs=12vdc 7.0 v with vs=3 .3vdc output load 50 pf operable temperature range - 55 +85 c storage temperature range - 55 +125 c enclosures type a type b type c package codes: code height ?h? pin length ?l? code height ?h? pin length ?l? code height ?h? pin length ? l? a1 1 0 .5 4.5 min. b1 12.7 na c1 1 1 . 3 na c2 15.0 na dimensions: mm dimensions: imm dimensions: mm 5 - pin version available, without pin 5 & 6 pin connections pin connections pin connections 1 supply voltage input (vs) 1 supply voltage input (vs) 1 electronic frequency control input (efc) 2 rf output 2 rf output 2 reference voltage output 3 ground (case) 3 ground (case) 3 supply voltage input (vs) 4 electronic frequency control input (efc) 4 electr onic frequency control input (efc) 4 rf output 5 n.c. or reference voltage output 5 n/c* 5 n/c* 6 rf output enable (option) 6 n.c. or rf output enable (option) version with 7 pins available see type b 7 reference voltage output 7 ground (case) * pin 5 must be remain unconnected. *pin 5 must be remain unconnected. *pin 5 must be remain unconnected.
vectron international www.vectron.com v. 2006 - 11 - 10 page 4 of 5 vectron international headquarters 267 lowell road hudson, new hampshire 03051 + 1 - 888 - 328 - 7661 tel + 1 - 888 - 329 - 8328 fax vectron international llc. 1 00 watts street mount holly springs, pa 17065 usa +1 - 717 - 486 - 3411 tel +1 - 717 - 486 - 5920 fax vectron international gmbh & co. kg landstrasse d - 74924 neckarbischofsheim germany +49 - 07268 - 801 - 0 tel +49 - 07268 - 801 - 281 fax vectron asia pacific sales office 1f - 2f, no 8 workshop, no 308 fenju road, waigaoqiao free trade zone, pudong, shanghai, p.r. china 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax c4500 ocxo standard shipping method *bei w 24 mm nur untere lochreihe * by w 24 mm only lower hole line gurtoberseite tape upper side gurtunterseite tape buttom side abwickelrichtung unwinding direction lage im gurt position in tape pin 1 a x p b k production tolerance complying din iec 286 - 3 enclosure type tape width w [mm] qu antity per meter quantity per reel dimension p type b and c 44 37.5 280 32 recommended reflow profile profile feature pb - free assembly /sn - pb assembly profile feature pb - free assembly /sn - pb assembly average r amp - up rate (t l to tp) 3c/second max. time 25c to peak temperature 8 minutes max. preheat - temperature min ts min ) - temperature min ts max ) - time (min to max) (ts) 150c 200c 60 - 180 seconds time maintai nted above - temperature (t l ) - time (t l ) 217c 60 - 150 seconds ts max to t l - ramp - up rate 3c/second max. time maintainted above - temperature (t l ) - time (t l ) 217c 60 - 150 seconds time within 5 c of actual peak temperature (tp) 20 - 40 seconds peak temperature (tp) max 260c ramp - down rate 6c/second max. note: all temperatures refer to topside of the package, measured on the package body surface. critical zone t l to t p ramp up ramp down t 25c to peak t p t e m p e r a t u r e t l 25 time ts ts ts preheat tp t l
vectron international www.vectron.com v. 2006 - 11 - 10 page 5 of 5 vectron international headquarters 267 lowell road hudson, new hampshire 03051 + 1 - 888 - 328 - 7661 tel + 1 - 888 - 329 - 8328 fax vectron international llc. 1 00 watts street mount holly springs, pa 17065 usa +1 - 717 - 486 - 3411 tel +1 - 717 - 486 - 5920 fax vectron international gmbh & co. kg landstrasse d - 74924 neckarbischofsheim germany +49 - 07268 - 801 - 0 tel +49 - 07268 - 801 - 281 fax vectron asia pacific sales office 1f - 2f, no 8 workshop, no 308 fenju road, waigaoqiao free trade zone, pudong, shanghai, p.r. china 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax c4500 ocxo how to order this product: step 1 use this worksheet to forward the following information to your factory representative : model stability code supply voltage code rf output code package code frequency control/ enable frequency c4500 d508 sv050 rfh a1 1 6mhz vs.operat. temp. range signal: tuning range: c508: 50ppb - 20 ?+70c rfh: hcmos 0: fixed ocxo; no adjust d107: 100ppb - 20 ?+70c 1: 1.0 ppm .. 2.5 ppm (sc) f157: 100ppb - 40 ?+85c 1: 3.0 pp m .. 8.0 ppm (at) d108: 10ppb - 20 ?+70c d208: 20ppb - 20 ?+70c enclosure: f258: 20ppb - 40 ?+85c a1: h: 10.5 l: 4. 5 min b1: h: 12.7 l: na supply: c1 : h: 11. 3 l: na c2: h: 15.0 l: na sv050: 5v sv120: 12v sv033: 3.3v step 2 the factory representative will then respond with a vectron model number in the following configuration: model package code dash dash number c450 0 [customer specified package code] - [factory generated 4 digit number] typical p/n = c450 0 a1 - 0001 notes: 1 contact factory for improved stabilities or additional product options. not all options and codes are available at all frequencies. 2 u nless otherwise stated all values are valid after warm - up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25c) 3 phase noise degrades with increasing output frequency. 4 subject to technical modific ation. 5 contact factory for availability.
|